Precise application in complex thin-walled anatomy. Benefit from high-pressure needle-free tissue-selective hydrodissection. Precise cutting with limited thermal damage and enhanced device flexibility and electrode stability. Tailor your own technique – with HYBRIDknife® flex.
ESGE Days 2025 Erbe Symposium – Empower your GI interventions: cutting-edge electrosurgery & hybrid technologies
ESGE Days 2025 Erbe Symposium – Empower your GI interventions Agenda: Chair: A. Repici, Italy / J. Jacques, Canada Deep dive into underwater resection in the GI tract – mastering techniques and electrosurgical settings; T. … Continue reading ESGE Days 2025 Erbe Symposium – Empower your GI interventions: cutting-edge electrosurgery & hybrid technologies
POEM using HybridKnife® I-Type with VIO® 3 and ERBEJET® 2
The POEM procedure (Peroral Endoscopic Myotomy), performed by Dr. Mohan Ramchandani, enables minimally invasive treatment of achalasia via endoscopic access through the esophageal mucosa. The HybridKnife® I-Type is used for submucosal injection and mucosal entry. … Continue reading POEM using HybridKnife® I-Type with VIO® 3 and ERBEJET® 2
Micro nozzle – HYBRIDknife® flex
Check out our new HYBRIDknife® flex with hybrid technology in 3rd space endoscopy. The thin electrode leads to a fine cutting result with low thermal damage.
Pressure needle-free injection, Part 1 – HYBRIDknife® flex
Check out our new HYBRIDknife® flex with hybrid technology in 3rd space endoscopy. The continuous generation of several smaller water cushions compared to an initial large cushion provides a good view of the operation site.
Pressure needle-free injection, Part 2 – HYBRIDknife® flex
Check out our new HYBRIDknife® flex with hybrid technology in 3rd space endoscopy. The high pressure injection enables a reliable separation of the submucosal tissue plane, even over a fold or submucosal fibrosis.
Flexibility and fixation – HYBRIDknife® flex
Check out our new HYBRIDknife® flex with hybrid technology in 3rd space endoscopy. The new flexibility improves working in retroflection.
ESD, gastric, for stomach neoplasia, with HYBRIDknife® flex, I-Type
HYBRIDknife® flex is an efficient instrument for applications in 3rd space endoscopy. In this case Dr. T. Beyna uses the HYBRIDknife® flex I-Type for endoscopic submucosal dissection (ESD) of stomach neoplasia. The VIO® 3 GI … Continue reading ESD, gastric, for stomach neoplasia, with HYBRIDknife® flex, I-Type
ESD, colon, splenic flexure, using HYBRIDknife® fIex, I-type
An endoscopic submucosal dissection (ESD) of a LST-NG tumor at the splenic flexure is performed by Prof. A. Repici using the VIO® 3 Gastroenterology Workstation with HYBRIDknife® flex I-Type. This monopolar knife is tailored for … Continue reading ESD, colon, splenic flexure, using HYBRIDknife® fIex, I-type
ESGE Days 2024 Erbe Symposium – Learning from the Experts: Advanced GI Resection Strategies
Take a subsequent look at the presentations from Berlin, listen to the statement and learn from the experts. The Erbe Symposium was chaired by Dr. Daniel von Renteln and Dr. Arnaud Lemmers. The following lectures … Continue reading ESGE Days 2024 Erbe Symposium – Learning from the Experts: Advanced GI Resection Strategies
DIES 2024 – Erbe Symposium / The knife of the future: experience with the new HYBRIDknife® flex
We were pleased to welcome a large number of renowned gastroenterologists during the DIES 2024 Erbe satellite symposium which was chaired by Prof. H. Neuhaus and Prof. A. Repici on February 2nd. If you were … Continue reading DIES 2024 – Erbe Symposium / The knife of the future: experience with the new HYBRIDknife® flex
DIES 2023 Erbe Symposium – Utilizing the lastest technologies in GI lesion management
Check out the talks from the Erbe symposium at the 25th Düsseldorf International Endoscopy Symposium (DIES) on February 3rd, 2023: Utilizing the latest technologies in GI lesion management, where Dr. Stavros Stavropoulos, Prof. Roberta Maselli, … Continue reading DIES 2023 Erbe Symposium – Utilizing the lastest technologies in GI lesion management
Advances in 3rd space endoscopy – ENDO 2022 Industry Symposium, Kyoto, JP
Lectures included: Stavros Stavropoulos (USA) Precise hybrid technology in 3rd space endoscopy Shaimaa Elkholy (Egypt) How to advance in 3rd space endoscopy Payal Saxena (Australia) Clinical advantage of using high-pressure cushioning performing POEM/ESD in challenging … Continue reading Advances in 3rd space endoscopy – ENDO 2022 Industry Symposium, Kyoto, JP
preciseSECT and HybridKnife for ESD and POEM – Infomercial
First performed at Endoscopy On Air 2021. The VIO® 3 preciseSECT mode together with the HybridKnife® is an ingenious technique for submucosal dissection in ESD and POEM procedures. The dynamic adjustment of the current curve … Continue reading preciseSECT and HybridKnife for ESD and POEM – Infomercial
POEM with HybridKnife® using preciseSECT – step by step descriptions on dissection and coagulation
Dr. Torsten Beyna, Evangelisches Krankenhaus Duesseldorf, Germany, demonstrates his performance of a peroral endoscopic myotomy (POEM) with the HybridKnife® I-type using the preciseSECT mode for submucosal dissection. Dr. Beyna emphasizes how to operate instrument and … Continue reading POEM with HybridKnife® using preciseSECT – step by step descriptions on dissection and coagulation
POEM using VIO® 3 preciseSECT mode with HybridKnife® – submucosal tunneling
The case shows the use of the VIO® 3 preciseSECT mode with HybridKnife® T-Type for the submucosal tunneling during a peroral endoscopic myotomy (POEM) performed by Dr. Honggang Yu. “For submucosal dissection in particularly well … Continue reading POEM using VIO® 3 preciseSECT mode with HybridKnife® – submucosal tunneling
Rectal ESD procedure using VIO® 3 preciseSECT mode with HybridKnife®
The case shows the application of the VIO® 3 preciseSECT mode for rectal ESD. “The preciseSECT mode in combination with the HybridKnife® I-type has a distinct behavior. It allows delicate control of dissection direction and … Continue reading Rectal ESD procedure using VIO® 3 preciseSECT mode with HybridKnife®
ESD with HybridKnife and VIO® 3
The integrated functions of waterjet surgery (ERBEJET® 2) and electrosurgery (VIO® 3) in the HybridKnife® constitutes the essential advantage of this instrument for performing endoscopic submucosal dissection (ESD) The individual steps – marking, elevation, incision/dissection … Continue reading ESD with HybridKnife and VIO® 3
POEM with HybridKnife®, VIO® 3 und ERBEJET® 2
Endoscopic treatment of esophageal achalasia demonstrating the advantages of HybridKnife®, VIO® 3 and ERBEJET® 2 for peroral endoscopic myotomy (POEM).
G-POEM with HybridKnife® and VIO® 3
Endoscopic treatment of gastroparesis demonstrating the advantages of HybridKnife®, VIO® 3 and ERBEJET® 2 for gastric peroral endoscopic myotomy (G-POEM).
Esophageal ESD with HybridKnife® O-Type and VIO® 3
The video demonstrates an endoscopic submucosal dissection (ESD) in the esophagus with HybridKnife® O-type, VIO® 3 and ERBEJET® 2. The endoscopist performs lateral j-shaped incisions followed by a c-shaped incision on the proximal side of … Continue reading Esophageal ESD with HybridKnife® O-Type and VIO® 3
HybridKnife® ESD Produkttrailer
HybridKnife® für die Endoskopische Submukosa Dissektion (ESD): Von der Markierung, Elevation, Inzision/Dissektion und Koagulation – alle Arbeitsschritte erfolgen mit nur einem Instrument, alle Funktionen sind ständig verfügbar. Auch größere Tumore können mit dem HybridKnife in … Continue reading HybridKnife® ESD Produkttrailer
ESD of recurrent colorectal adenoma with HybridKnife®
After numerous endoscopic mucosal resection (EMR) attempts an en bloc endoscopic submucosal dissection (ESD) of the colorectal cancer with HybridKnife® was indicated. A partial muscle layer resection must also be carried out due to serious … Continue reading ESD of recurrent colorectal adenoma with HybridKnife®
ESD of LST-NG tumor in distal sigmoid colon with HybridKnife®
The integrated functions of waterjet surgery and electrosurgery in the HybridKnife enable endoscopic submucosal dissection (ESD) of a LST-NG (laterally spreading, non-granular type) tumor in the distal sigmoid colon.R0 resection of the adenoma with high … Continue reading ESD of LST-NG tumor in distal sigmoid colon with HybridKnife®
ESD for early gastric cancer using HybridKnife®
Waterjet elevation with the ERBEJET 2 and the HybridKnife prior to endoscopic submucosal dissection (ESD) is a protective and selective procedure. Selective elevation of the mucosa using a submucosal fluid cushion raises the resection level … Continue reading ESD for early gastric cancer using HybridKnife®
Endoskopische Submukosa-Dissektion (ESD) mit HybridKnife®
HybridKnife bei der Endoskopischen Submukosa Dissektion (ESD): von der Markierung, Elevation, Inzision/Dissektion und Koagulation – alle Arbeitsschritte erfolgen mit nur einem Instrument, alle Funktionen sind ständig verfügbar. Auch größere Tumore können in R0-Technik und vor … Continue reading Endoskopische Submukosa-Dissektion (ESD) mit HybridKnife®
En-bloc-Resektion von Blasentumoren mit HybridKnife
Mit der elektrochirurgischen Funktion des HybridKnife-Instruments kann der Blasentumor am Stück reseziert werden. Durch die Elevation der Mukosa wird die Resektionsebene angehoben und das Risiko einer Perforation der Muskularis gesenkt.
STER mit HybridKnife®
Endoskopische Resektion von submukosalen Tumoren mit dem HybridKnife® von Erbe. Das HybridKnife® vereint die Technologien Elektro- und Wasserstrahl-Chirurgie in einem Instrument. Das Ergebnis: eine intakte Mukosa und geschonte Muskularis.
Webcast – ESD using HybridKnife
Presented by Dr. Arjun D. Koch Gastroenterology and Hepatology Erasmus MC, Rotterdam, Netherlands Contents: 1. ESD strategy 2. Hybrid = electrosurgery and waterjet 3. Cutting plane for submucosal dissection 4. Different approach in every organ … Continue reading Webcast – ESD using HybridKnife
Peroral endoscopic myotomy (POEM) with HybridKnife T-Type
The multifunctional HybridKnife instrument not only supports the POEM procedure, it also simplifies the relevant steps. Thanks to the integrated electrosurgical and waterjet functions, both the time and effort required for peroral endoscopic myotomy is … Continue reading Peroral endoscopic myotomy (POEM) with HybridKnife T-Type
POEM mit HybridKnife®, I-Typ
HybridKnife® optimiert die perorale, endoskopische Myotomie und vereinfacht die POEM-Arbeitsschritte. Mit Hilfe der Wasserstrahl-Elevation (ERBEJET 2) wird die Mukosa vor der Dissektion angehoben. Dieser Eingriff wurde von Prof. Dr. med H. Neuhaus mit dem HybridKnife … Continue reading POEM mit HybridKnife®, I-Typ
POEM (submucosal tunneling) with HybridKnife®
HybridKnife from Erbe optimizes Peroral Endoscopic Myotomy (POEM). The multifunctional HybridKnife instrument not only supports the POEM procedure, it also simplifies the relevant steps, especially the creation of a submucosal tunnel. Waterjet elevation establishes a … Continue reading POEM (submucosal tunneling) with HybridKnife®
