Joe, young man from USA: “To my shock, I discovered blood in my stool. The gastroenterologist diagnosed me with a large polyp in my colon. I was worried a lot. Surgery could lead to permanent … Continue reading Large polyp in the colon – EXCEPTIONAL PATIENT STORIES
ESGE Days Dublin 2023 – Erbe-Symposium: Tips and Tricks of Electrosurgery
The symposium, moderated by Professors Horst Neuhaus (Germany) and Alessandro Repici (Italy), featured renowned gastroenterologists who presented interesting and informative lectures. The event was a success, showcasing the importance of training in electrosurgery, with the … Continue reading ESGE Days Dublin 2023 – Erbe-Symposium: Tips and Tricks of Electrosurgery
DIES 2023 Erbe Symposium – Utilizing the lastest technologies in GI lesion management
Check out the talks from the Erbe symposium at the 25th Düsseldorf International Endoscopy Symposium (DIES) on February 3rd, 2023: Utilizing the latest technologies in GI lesion management, where Dr. Stavros Stavropoulos, Prof. Roberta Maselli, … Continue reading DIES 2023 Erbe Symposium – Utilizing the lastest technologies in GI lesion management
preciseSECT and HybridKnife for ESD and POEM – Infomercial
First performed at Endoscopy On Air 2021. The VIO® 3 preciseSECT mode together with the HybridKnife® is an ingenious technique for submucosal dissection in ESD and POEM procedures. The dynamic adjustment of the current curve … Continue reading preciseSECT and HybridKnife for ESD and POEM – Infomercial
POEM with HybridKnife® using preciseSECT – step by step descriptions on dissection and coagulation
Dr. Torsten Beyna, Evangelisches Krankenhaus Duesseldorf, Germany, demonstrates his performance of a peroral endoscopic myotomy (POEM) with the HybridKnife® I-type using the preciseSECT mode for submucosal dissection. Dr. Beyna emphasizes how to operate instrument and … Continue reading POEM with HybridKnife® using preciseSECT – step by step descriptions on dissection and coagulation
POEM using VIO® 3 preciseSECT mode with HybridKnife® – submucosal tunneling
The case shows the use of the VIO® 3 preciseSECT mode with HybridKnife® T-Type for the submucosal tunneling during a peroral endoscopic myotomy (POEM) performed by Dr. Honggang Yu. “For submucosal dissection in particularly well … Continue reading POEM using VIO® 3 preciseSECT mode with HybridKnife® – submucosal tunneling
Rectal ESD procedure using VIO® 3 preciseSECT mode with HybridKnife®
The case shows the application of the VIO® 3 preciseSECT mode for rectal ESD. “The preciseSECT mode in combination with the HybridKnife® I-type has a distinct behavior. It allows delicate control of dissection direction and … Continue reading Rectal ESD procedure using VIO® 3 preciseSECT mode with HybridKnife®
Tissue ablation for metal stent ingrowth with APC 3 using FiAPC® probe 2200A in forcedAPC mode
Here we report the case of a 61 year-old-woman who underwent total gastrectomy for cardial adenocarcinoma. Few days later, she developed anastomotic dehiscence, endoscopically treated with stent-in-stent technique. Implementation of a partially covered self-expandable-metal-stent (SEMS) … Continue reading Tissue ablation for metal stent ingrowth with APC 3 using FiAPC® probe 2200A in forcedAPC mode
Radiation proctitis treated with preciseAPC® and pulsedAPC® mode
Radiation proctitis represents a condition that affects patients even years after radiotherapy for pelvic tumors. Chronic bleeding can lead to anemia, even with need for blood transfusion. The quality of life is affected by this … Continue reading Radiation proctitis treated with preciseAPC® and pulsedAPC® mode
EMR for lateral spreading tumors (LST) with HybridAPC margin ablation
In a piecemeal EMR, neoplastic tissue may remain at the edge or surface of the resection, which can be the cause of a local recurrence. Thermal ablation after EMR can reduce the recurrence rate by … Continue reading EMR for lateral spreading tumors (LST) with HybridAPC margin ablation
Treatment of angiodysplasia with FiAPC® probe 1500 A using preciseAPC® mode
Angiodysplasias in all sections of the gastrointestinal tract can be treated successfully using argon plasma coagulation. The aim is to avoid recurrent bleeding. Angiodysplasias often occur in the small intestine and can be treated with … Continue reading Treatment of angiodysplasia with FiAPC® probe 1500 A using preciseAPC® mode
Targeted therapy of radiation proctitis with FiAPC probe, APC 3 and VIO® 3 using the preciseAPC mode
Radiation proctitis represents a condition which can occur even years after radiotherapy for pelvic disease. Complications can severely affect life quality and are sometimes challenging for the endoscopist. Our FiAPC probes in combination with VIO® … Continue reading Targeted therapy of radiation proctitis with FiAPC probe, APC 3 and VIO® 3 using the preciseAPC mode
ESD with HybridKnife and VIO® 3
The integrated functions of waterjet surgery (ERBEJET® 2) and electrosurgery (VIO® 3) in the HybridKnife® constitutes the essential advantage of this instrument for performing endoscopic submucosal dissection (ESD) The individual steps – marking, elevation, incision/dissection … Continue reading ESD with HybridKnife and VIO® 3
EMR with VIO® 3 using endoCUT® Q mode
VIO® 3 offers you all the suitable modes for your gastrointestinal application, and your chosen working instrument (e.g. electrosurgical loop or needle). Optimized performance parameters in the endoCUT® Q mode enables effective endocopic mucosal resection … Continue reading EMR with VIO® 3 using endoCUT® Q mode
POEM with HybridKnife®, VIO® 3 und ERBEJET® 2
Endoscopic treatment of esophageal achalasia demonstrating the advantages of HybridKnife®, VIO® 3 and ERBEJET® 2 for peroral endoscopic myotomy (POEM).
G-POEM with HybridKnife® and VIO® 3
Endoscopic treatment of gastroparesis demonstrating the advantages of HybridKnife®, VIO® 3 and ERBEJET® 2 for gastric peroral endoscopic myotomy (G-POEM).
POEM with HybridKnife® and VIO® 3 using the preciseSECT mode for submucosal tunneling
PreciseSECT mode for peroral endoscopic myotomy (POEM) with VIO® 3 and HybridKnife® is a new option for precise submucosal tunneling. Dynamic adjustment of the modulation frequency makes the preciseSECT mode ideally suited for selective dissection … Continue reading POEM with HybridKnife® and VIO® 3 using the preciseSECT mode for submucosal tunneling
Esophageal ESD with HybridKnife® O-Type and VIO® 3
The video demonstrates an endoscopic submucosal dissection (ESD) in the esophagus with HybridKnife® O-type, VIO® 3 and ERBEJET® 2. The endoscopist performs lateral j-shaped incisions followed by a c-shaped incision on the proximal side of … Continue reading Esophageal ESD with HybridKnife® O-Type and VIO® 3
Zenker’s diverticulotomy with APC 2
Argon plasma coagulation (APC) for flexible endoscopic therapy of Zenker’s diverticulum is effective and reliable. Compared to other methods it offers the advantage of an efficient hemostasis.
Wasserstrahl-unterstützte EMR eines Rektumadenoms mit der GI-Workstation
Die nadellose Wasserstrahl-Elevation mit dem ERBEJET® 2 der GI-Workstation (besteht noch aus VIO® 200 D, APC 2, ENDO CUT® Q) hebt die Mukosa schnell und selektiv an. Das erzeugte Flüssigkeitskissen ist größer als bei einer … Continue reading Wasserstrahl-unterstützte EMR eines Rektumadenoms mit der GI-Workstation
Teleangiectasia, hemostasis with APC 2
Effective hemostasis in case of hemorrhagic teleangiectasia using a flexible APC probe. The PRECISE APC mode is provided by the VIO Generator and the APC 2 module of a Gastroenterology Workstation.
HybridKnife® ESD Produkttrailer
HybridKnife® für die Endoskopische Submukosa Dissektion (ESD): Von der Markierung, Elevation, Inzision/Dissektion und Koagulation – alle Arbeitsschritte erfolgen mit nur einem Instrument, alle Funktionen sind ständig verfügbar. Auch größere Tumore können mit dem HybridKnife in … Continue reading HybridKnife® ESD Produkttrailer
ESD of recurrent colorectal adenoma with HybridKnife®
After numerous endoscopic mucosal resection (EMR) attempts an en bloc endoscopic submucosal dissection (ESD) of the colorectal cancer with HybridKnife® was indicated. A partial muscle layer resection must also be carried out due to serious … Continue reading ESD of recurrent colorectal adenoma with HybridKnife®
ESD of LST-NG tumor in distal sigmoid colon with HybridKnife®
The integrated functions of waterjet surgery and electrosurgery in the HybridKnife enable endoscopic submucosal dissection (ESD) of a LST-NG (laterally spreading, non-granular type) tumor in the distal sigmoid colon.R0 resection of the adenoma with high … Continue reading ESD of LST-NG tumor in distal sigmoid colon with HybridKnife®
ESD for early gastric cancer using HybridKnife®
Waterjet elevation with the ERBEJET 2 and the HybridKnife prior to endoscopic submucosal dissection (ESD) is a protective and selective procedure. Selective elevation of the mucosa using a submucosal fluid cushion raises the resection level … Continue reading ESD for early gastric cancer using HybridKnife®
Eradication of residual Barrett´s mucosa with HybridAPC
Argon Plasma Coagulation (APC) has been used for thermal ablation of Barrett’s esophagus for years. The flexible HybridAPC probe from Erbe combines now APC with waterjet elevation to create a submucosal protective layer. HybridAPC enables … Continue reading Eradication of residual Barrett´s mucosa with HybridAPC
Endoskopische Submukosa-Dissektion (ESD) mit HybridKnife®
HybridKnife bei der Endoskopischen Submukosa Dissektion (ESD): von der Markierung, Elevation, Inzision/Dissektion und Koagulation – alle Arbeitsschritte erfolgen mit nur einem Instrument, alle Funktionen sind ständig verfügbar. Auch größere Tumore können in R0-Technik und vor … Continue reading Endoskopische Submukosa-Dissektion (ESD) mit HybridKnife®
Wasserstrahl-unterstützte EMR im Colon ascendens mit ERBEJET® 2
Die nadellose Wasserstrahl-Elevation mit dem ERBEJET 2 hebt die Mukosa schnell und selektiv an. Das erzeugte Flüssigkeitskissen ist größer als bei einer Nadelinjektion. Dieses Kissen bildet einen Sicherheitsabstand zur Muskularis. Dadurch wird das Perforationsrisiko bei … Continue reading Wasserstrahl-unterstützte EMR im Colon ascendens mit ERBEJET® 2
STER mit HybridKnife®
Endoskopische Resektion von submukosalen Tumoren mit dem HybridKnife® von Erbe. Das HybridKnife® vereint die Technologien Elektro- und Wasserstrahl-Chirurgie in einem Instrument. Das Ergebnis: eine intakte Mukosa und geschonte Muskularis.
Ablation of esophageal stent ingrowth with APC 2
Proliferation of tumor tissue through the mesh of the esophageal stent often occurs when using non-coated metal stents. Argon plasma coagulation (APC) with flexible probes have proved to be very effective in removing such in- … Continue reading Ablation of esophageal stent ingrowth with APC 2
Ablation of colorectal neoplasia using APC 2
Thermal ablation of colorectal neoplasia with argon plasma coagulation (APC). Performed with the PULSED APC mode of the APC 2 from Erbe. Flexible APC probes with axial and lateral openings are applied.
Thermal ablation of Barrett´s remainder at GEJ with HybridAPC
Argon Plasma Coagulation (APC) has been used for thermal ablation of Barrett’s esophagus for years. The flexible HybridAPC probe from Erbe combines now APC with waterjet elevation to create a submucosal protective layer. HybridAPC enables … Continue reading Thermal ablation of Barrett´s remainder at GEJ with HybridAPC
Ablation des Barrett-Ösophagus mit HybridAPC
Beim HybridAPC-Verfahren wird die Argonplasma-Koagulation (APC) jetzt mit einer Wasserstrahl-Funktion kombiniert. Vor der Ablation wird die Mukosa mit dem Hochdruck-Wasserstrahls der flexiblen HybridAPC-Sonde angehoben. Die vom Barrett befallene Mukosa kann durch das entstandene Wasserschutzkissen mit … Continue reading Ablation des Barrett-Ösophagus mit HybridAPC
Polypectomy using ENDO CUT® Q
Alternating cutting and coagulation during polypectomy of a stalked polyp in the colon using VIO ENDO CUT Q Mode.
Peroral endoscopic myotomy (POEM) with HybridKnife T-Type
The multifunctional HybridKnife instrument not only supports the POEM procedure, it also simplifies the relevant steps. Thanks to the integrated electrosurgical and waterjet functions, both the time and effort required for peroral endoscopic myotomy is … Continue reading Peroral endoscopic myotomy (POEM) with HybridKnife T-Type
POEM mit HybridKnife®, I-Typ
HybridKnife® optimiert die perorale, endoskopische Myotomie und vereinfacht die POEM-Arbeitsschritte. Mit Hilfe der Wasserstrahl-Elevation (ERBEJET 2) wird die Mukosa vor der Dissektion angehoben. Dieser Eingriff wurde von Prof. Dr. med H. Neuhaus mit dem HybridKnife … Continue reading POEM mit HybridKnife®, I-Typ
POEM (submucosal tunneling) with HybridKnife®
HybridKnife from Erbe optimizes Peroral Endoscopic Myotomy (POEM). The multifunctional HybridKnife instrument not only supports the POEM procedure, it also simplifies the relevant steps, especially the creation of a submucosal tunnel. Waterjet elevation establishes a … Continue reading POEM (submucosal tunneling) with HybridKnife®
Papillotomy using ENDO CUT® I
The fractionated cutting mode ENDO CUT I is characterized by alternating cutting and coagulation cycles. This makes it possible to carry out controlled cutting with sufficient hemostasis during the entire cutting process, which supports the … Continue reading Papillotomy using ENDO CUT® I
Hemostasis of gastrointestinal bleeding using APC 2
Argon plasma coagulation (APC) treatment of ulcer-bed Forrest 1b bleeding with PULSED APC, Effect 2.