Optimize the balance between dissection speed, thermal impact, and sealing. Dissection and sealing in a true single step workflow. Plug in TriSect rapide® and enjoy working with our customized modes thermoSECT or softCOAG® on your … Continue reading TriSect rapide® – Dissect & Seal in a True Single Step
Nerve-sparing laparoscopic sacral colpopexy using VIO® 3 thermoSEAL® and preciseSECT mode
This nerve-sparing laparoscopic sacral colpopexy is performed in combination of the BiClamp® LAP with the VIO® 3 thermoSEAL mode and a monopolar scissor with the VIO® 3 preciseSECT mode make a fast, precise and hemostatic … Continue reading Nerve-sparing laparoscopic sacral colpopexy using VIO® 3 thermoSEAL® and preciseSECT mode
Precise hybrid technology in 3rd space endoscopy – Pre DIES 2022 online workshop
Speaking at the 24 th Düsseldorf International Endoscopy Symposium 2022 online workshop, Drs. Torsten Beyna and Roberta Maselli delivered an insightful lecture reviewing advances and benefits of Erbe’s hybrid technology in 3rd space endoscopy. Beginning … Continue reading Precise hybrid technology in 3rd space endoscopy – Pre DIES 2022 online workshop
POEM with HybridKnife® using preciseSECT – step by step descriptions on dissection and coagulation
Dr. Torsten Beyna, Evangelisches Krankenhaus Duesseldorf, Germany, demonstrates his performance of a peroral endoscopic myotomy (POEM) with the HybridKnife® I-type using the preciseSECT mode for submucosal dissection. Dr. Beyna emphasizes how to operate instrument and … Continue reading POEM with HybridKnife® using preciseSECT – step by step descriptions on dissection and coagulation
Rectal ESD procedure using VIO® 3 preciseSECT mode with HybridKnife®
The case shows the application of the VIO® 3 preciseSECT mode for rectal ESD. “The preciseSECT mode in combination with the HybridKnife® I-type has a distinct behavior. It allows delicate control of dissection direction and … Continue reading Rectal ESD procedure using VIO® 3 preciseSECT mode with HybridKnife®
Radiation proctitis treated with preciseAPC® and pulsedAPC® mode
Radiation proctitis represents a condition that affects patients even years after radiotherapy for pelvic tumors. Chronic bleeding can lead to anemia, even with need for blood transfusion. The quality of life is affected by this … Continue reading Radiation proctitis treated with preciseAPC® and pulsedAPC® mode
ESD with HybridKnife and VIO® 3
The integrated functions of waterjet surgery (ERBEJET® 2) and electrosurgery (VIO® 3) in the HybridKnife® constitutes the essential advantage of this instrument for performing endoscopic submucosal dissection (ESD) The individual steps – marking, elevation, incision/dissection … Continue reading ESD with HybridKnife and VIO® 3
EMR with VIO® 3 using endoCUT® Q mode
VIO® 3 offers you all the suitable modes for your gastrointestinal application, and your chosen working instrument (e.g. electrosurgical loop or needle). Optimized performance parameters in the endoCUT® Q mode enables effective endocopic mucosal resection … Continue reading EMR with VIO® 3 using endoCUT® Q mode
G-POEM with HybridKnife® and VIO® 3
Endoscopic treatment of gastroparesis demonstrating the advantages of HybridKnife®, VIO® 3 and ERBEJET® 2 for gastric peroral endoscopic myotomy (G-POEM).
VIO® 3 success factors
What makes the VIO® 3 so successful? Take a look at the reports from all over the world.
POEM with HybridKnife® and VIO® 3 using the preciseSECT mode for submucosal tunneling
PreciseSECT mode for peroral endoscopic myotomy (POEM) with VIO® 3 and HybridKnife® is a new option for precise submucosal tunneling. Dynamic adjustment of the modulation frequency makes the preciseSECT mode ideally suited for selective dissection … Continue reading POEM with HybridKnife® and VIO® 3 using the preciseSECT mode for submucosal tunneling
Esophageal ESD with HybridKnife® O-Type and VIO® 3
The video demonstrates an endoscopic submucosal dissection (ESD) in the esophagus with HybridKnife® O-type, VIO® 3 and ERBEJET® 2. The endoscopist performs lateral j-shaped incisions followed by a c-shaped incision on the proximal side of … Continue reading Esophageal ESD with HybridKnife® O-Type and VIO® 3
Surgical treatment of deep infiltrating rectocervical endometriosis using Lap BiSect Micro and BiClamp® LAP powered by VIO® 3
The LAP BiSect enables laparoscopic endometriosis surgery with its precise bipolar cutting and coagulation features. In addition the BiClamp LAP could be used to seal tissue bundles permanently and effectively. The VIO® 3 electrosurgical unit … Continue reading Surgical treatment of deep infiltrating rectocervical endometriosis using Lap BiSect Micro and BiClamp® LAP powered by VIO® 3
Extended PLND for high risk prostate cancer using VIO® 3 preciseSECT
The preciseSECT mode of the VIO® 3 is ideally suited for precise dissection during radical prostatectomy. The video focuses on the anatomical extended pelvic lymph node dissection (PLND) and shows for example the dissection … Continue reading Extended PLND for high risk prostate cancer using VIO® 3 preciseSECT
VIO® 3 Elektrochirurgie-gerät
Die Elektrochirurgie wird von Erbe geprägt und zu der Spitzentechnologie ausgebaut, wie sie heute im OP eingesetzt wird. VIO 3 ist ein weiterer technologischer Meilenstein. Die Bedienung des VIO 3 haben wir für Sie so … Continue reading VIO® 3 Elektrochirurgie-gerät
preciseSECT – der neue VIO-3-Mode
Durch die dynamische Anpassung der Modulationsfrequenz eignet sich der preciseSECT-Mode des VIO 3 perfekt, um feine Gewebestrukturen zu präparieren. preciseSECT bietet eine schnelle und effektive Koagulation mit begrenzt gewebetrennenden Eigenschaften, bei geringer Rauchentwicklung und Karbonisation.
TEM-ESD using the preciseSECT VIO 3 mode
The preciseSECT VIO 3 mode is particularly well suited to dissect the submucosa during a transanal, microsurgical, endoscopic submucosal dissection, TEM-ESD for short.
VIO® 3 Setup
Die Bedienung des VIO® 3 Schritt für Schritt.
TME using the preciseSECT VIO 3 mode
The preciseSECT mode of the VIO® 3 is particularly well suited to mobilize the left colonic flexure and precisly dissect the mesorectum during a total mesorectal excision, TME for short.