Bipolar transcervical resection (TCR) of myomas with VIO® 3 and 18.5 CH Mini resectoscope. Imaging with VIRON 1 System

The transcervical resection solution combines the VIRON 1 Imaging System with our VIO® 3 electrosurgical unit and the bipolar 18.5 CH Mini resectoscope. The highCUT bipolar mode of the VIO® 3 enables immediate, delay-free incision … Continue reading Bipolar transcervical resection (TCR) of myomas with VIO® 3 and 18.5 CH Mini resectoscope. Imaging with VIRON 1 System

TCRF – Bipolar transcervical resection of fibroids with VIO® 3 and 18.5 CH Mini resectoscope. Imaged by VIRON 1 System.

The transcervical resection solution combines the VIRON 1 Imaging System with our VIO® 3 electrosurgical unit and the bipolar 18.5 CH Mini resectoscope. The highCUT bipolar mode of the VIO® 3 enables immediate, delay-free incision … Continue reading TCRF – Bipolar transcervical resection of fibroids with VIO® 3 and 18.5 CH Mini resectoscope. Imaged by VIRON 1 System.

Hysterectomy in case of laparoscopic treatment of deep infiltrating endometriosis (DIE) using TriSect rapide®

See the TriSect rapide® in use at a laparoscopic hysterectomy. The multi-tool dissects and excises the fallopian tube, transects the ovarian, round and broad ligaments, and dissects ureter and uterine pedicles. TriSect rapide is powered … Continue reading Hysterectomy in case of laparoscopic treatment of deep infiltrating endometriosis (DIE) using TriSect rapide®

Electrosurgical adhesiolysis and dissection of endometriotic lesions in case of DIE using TriSect rapide®

Endometriosis electrosurgery removes endometriotic lesions and adhesions. The TriSect rapide® is ideally suitable for open and laparoscopic treatment of deep infiltrating endometriosis (DIE). Here you can follow the laparoscopic approach using this multi-tool powered by … Continue reading Electrosurgical adhesiolysis and dissection of endometriotic lesions in case of DIE using TriSect rapide®

Mini-probe cryobiopsy of peripheral pulmonary nodules with different targeting approaches – General considerations

Watch generic considerations on peripheral sampling. Rationales for cryobiopsy technique are highlighted, including safety profile and advantages over competing modalities (eccentric positioning, molecular target testing). Furthermore, contra-indications are highlighted. Construction of a bronchoscopy suite with … Continue reading Mini-probe cryobiopsy of peripheral pulmonary nodules with different targeting approaches – General considerations

BiClamp® LAP and LAP BiSect in gynecological surgery – a testimonial by Dr. Ma Li, University Hospital Singapore

Sealing of vessels and tissue structures and precise bipolar dissection are important working steps in gynecological surgeries. Erbe therefore provides reliable and reusable surgical instruments – BiClamp® LAP and LAP BiSect Micro. Dr. Ma Li … Continue reading BiClamp® LAP and LAP BiSect in gynecological surgery – a testimonial by Dr. Ma Li, University Hospital Singapore

Sampling of peripheral lung nodules with cryo – ERS Congress 2021

Before tailored immunotherapeutic therapy in patients with pulmonary malignancies, high quality peripheral sampling is in order. Learn about the latest results from Prof. Herth and how he diagnoses peripheral pulmonary lesions with modern cryotechnology.

Blood clot cryoextraction – ERS Congress 2021

How to rapidly restore airway patency in a patient with a blood cast of the tracheobronchial tree? See Prof. Hetzel discuss how to perform cryoextraction of these blood clots.

POEM with HybridKnife® using preciseSECT – step by step descriptions on dissection and coagulation

Dr. Torsten Beyna, Evangelisches Krankenhaus Duesseldorf, Germany, demonstrates his performance of a peroral endoscopic myotomy (POEM) with the HybridKnife® I-type using the preciseSECT mode for submucosal dissection. Dr. Beyna emphasizes how to operate instrument and … Continue reading POEM with HybridKnife® using preciseSECT – step by step descriptions on dissection and coagulation

Tissue ablation for metal stent ingrowth with APC 3 using FiAPC® probe 2200A in forcedAPC mode

Here we report the case of a 61 year-old-woman who underwent total gastrectomy for cardial adenocarcinoma. Few days later, she developed anastomotic dehiscence, endoscopically treated with stent-in-stent technique. Implementation of a partially covered self-expandable-metal-stent (SEMS) … Continue reading Tissue ablation for metal stent ingrowth with APC 3 using FiAPC® probe 2200A in forcedAPC mode

Transbronchial cryobiopsy with rigid intubation for ILD diagnosis using flexible single-use cryoprobe and ERBECRYO® 2

To diagnose ILD, the flexible single-use cryoprobe with 1.7 mm was advanced into the periphery until the pleura and pulled back for 1cm. Fluoroscopy control was used for the positioning. After freezing for 5 seconds, … Continue reading Transbronchial cryobiopsy with rigid intubation for ILD diagnosis using flexible single-use cryoprobe and ERBECRYO® 2

Total laparoscopic hysterectomy (TLH) for adenomyosis with BiClamp® LAP forceps and LAP BiSect Micro

Adenomyosis represents a disorder affecting more young women than previously suspected. As endometrial glands and stroma appear in the myometrium, the enlarged uterus can cause symptoms such as dysmenorrhea, infertility and pain. A negative effect … Continue reading Total laparoscopic hysterectomy (TLH) for adenomyosis with BiClamp® LAP forceps and LAP BiSect Micro

Targeted therapy of radiation proctitis with FiAPC probe, APC 3 and VIO® 3 using the preciseAPC mode

Radiation proctitis represents a condition which can occur even years after radiotherapy for pelvic disease. Complications can severely affect life quality and are sometimes challenging for the endoscopist. Our FiAPC probes in combination with VIO® … Continue reading Targeted therapy of radiation proctitis with FiAPC probe, APC 3 and VIO® 3 using the preciseAPC mode

G-POEM with HybridKnife® and VIO® 3

Endoscopic treatment of gastroparesis demonstrating the advantages of HybridKnife®, VIO® 3 and ERBEJET® 2 for gastric peroral endoscopic myotomy (G-POEM).

Surgical treatment of deep infiltrating rectocervical endometriosis using Lap BiSect Micro and BiClamp® LAP powered by VIO® 3

The LAP BiSect enables laparoscopic endometriosis surgery with its precise bipolar cutting and coagulation features. In addition the BiClamp LAP could be used to seal tissue bundles permanently and effectively. The VIO® 3 electrosurgical unit … Continue reading Surgical treatment of deep infiltrating rectocervical endometriosis using Lap BiSect Micro and BiClamp® LAP powered by VIO® 3

Zenker’s diverticulotomy with APC 2

Argon plasma coagulation (APC) for flexible endoscopic therapy of Zenker’s diverticulum is effective and reliable. Compared to other methods it offers the advantage of an efficient hemostasis.

Cystectomy, laparoscopic, with BiCision®

Vessel sealing and dissection with a single instrument during a laparoscopic cystectomy. BiCision® maximizes the thermofusion zone and minimizes the risk of thermal injury to sensitive structures in urologic surgery, such as ureter or nerves.

ToBi – mikroskopische Tonsillektomie mit BiClamp® 150 C

Mikroskopische Gefäßdarstellung und wirksame Gefäßversiegelung mit der BiClamp 150 C führt zu einer neuen Methode der Tonsillektomie ohne Nachblutungen, die Dr. Dr. Jürgen Abrams vorstellt, und die er ToBi nennt.

TEM-ESD using the preciseSECT VIO 3 mode

The preciseSECT VIO 3 mode is particularly well suited to dissect the submucosa during a transanal, microsurgical, endoscopic submucosal dissection, TEM-ESD for short.

Teleangiectasia, hemostasis with APC 2

Effective hemostasis in case of hemorrhagic teleangiectasia using a flexible APC probe. The PRECISE APC mode is provided by the VIO Generator and the APC 2 module of a Gastroenterology Workstation.

LASH with BiCision®

Effective sealing and dissection of vessels and ligaments with BiCision® during a laparoscopic supracervical hysterectomy (LASH).

Chalazion removal with monopolar electrode

The favorable hemostasis properties of the new VIO C mode permit precise dissection and removal of eye cysts (chalazin) using a monopolar tungsten electrode.