Effective hemostasis in case of hemorrhagic teleangiectasia using a flexible APC probe. The PRECISE APC mode is provided by the VIO Generator and the APC 2 module of a Gastroenterology Workstation.

Effective hemostasis in case of hemorrhagic teleangiectasia using a flexible APC probe. The PRECISE APC mode is provided by the VIO Generator and the APC 2 module of a Gastroenterology Workstation.
Reliable vessel sealing with BiClamp® LAP forceps during a total laparoscopic hysterectomy (TLH). The procedure is performed by D. Sarlos, MD, Kantonsspital Aarau, Switzerland. 1. Dissection of the Fallopian tube from the uterus 2. Ovary … Continue reading Total laparoscopic hysterectomy (TLH) with BiClamp® LAP forceps
The new LAP BiSect Micro is ideally suited for precise bipolar dissection, e.g.for exposing the bladder neck during a laparoscopic prostatectomy procedure. The BiClamp LAP is used for the sealing of larger vessels.
HybridKnife® für die Endoskopische Submukosa Dissektion (ESD): Von der Markierung, Elevation, Inzision/Dissektion und Koagulation – alle Arbeitsschritte erfolgen mit nur einem Instrument, alle Funktionen sind ständig verfügbar. Auch größere Tumore können mit dem HybridKnife in … Continue reading HybridKnife® ESD Produkttrailer
Bei der Leberresektion trennt der Wasserstrahl des ERBEJET 2 gewebeselektiv zwischen Parenchym und Blutgefäßen sowie Gallengängen. Weiches Parenchym wird ausgespült, während die Netzstruktur der Blutgefäße erhalten bleibt und blutungsarm versorgt werden kann. Die Eingriffszeit wird … Continue reading Hemihepatektomie, rechts, mit ERBEJET® 2
After numerous endoscopic mucosal resection (EMR) attempts an en bloc endoscopic submucosal dissection (ESD) of the colorectal cancer with HybridKnife® was indicated. A partial muscle layer resection must also be carried out due to serious … Continue reading ESD of recurrent colorectal adenoma with HybridKnife®
The integrated functions of waterjet surgery and electrosurgery in the HybridKnife enable endoscopic submucosal dissection (ESD) of a LST-NG (laterally spreading, non-granular type) tumor in the distal sigmoid colon.R0 resection of the adenoma with high … Continue reading ESD of LST-NG tumor in distal sigmoid colon with HybridKnife®
Waterjet elevation with the ERBEJET 2 and the HybridKnife prior to endoscopic submucosal dissection (ESD) is a protective and selective procedure. Selective elevation of the mucosa using a submucosal fluid cushion raises the resection level … Continue reading ESD for early gastric cancer using HybridKnife®
Argon Plasma Coagulation (APC) has been used for thermal ablation of Barrett’s esophagus for years. The flexible HybridAPC probe from Erbe combines now APC with waterjet elevation to create a submucosal protective layer. HybridAPC enables … Continue reading Eradication of residual Barrett´s mucosa with HybridAPC
The fine power setting of the AUTO CUT and other modes of the VIO C from Erbe provides optimal cutting and preparation results. Please see therefore the surgical treatment of a turned in eyelid (entropion) … Continue reading Eyelid surgery for entropion using VIO C
The favorable hemostasis properties of the new VIO C mode permit precise dissection and removal of eye cysts (chalazin) using a monopolar tungsten electrode.
HybridKnife bei der Endoskopischen Submukosa Dissektion (ESD): von der Markierung, Elevation, Inzision/Dissektion und Koagulation – alle Arbeitsschritte erfolgen mit nur einem Instrument, alle Funktionen sind ständig verfügbar. Auch größere Tumore können in R0-Technik und vor … Continue reading Endoskopische Submukosa-Dissektion (ESD) mit HybridKnife®
The bipolar VIO resection mode provides optimal hemostatic properties and enables an optimal initial incision with continious cutting. For example during transcervical resection of the endometrium (TCRE).
Mit der elektrochirurgischen Funktion des HybridKnife-Instruments kann der Blasentumor am Stück reseziert werden. Durch die Elevation der Mukosa wird die Resektionsebene angehoben und das Risiko einer Perforation der Muskularis gesenkt.
Die nadellose Wasserstrahl-Elevation mit dem ERBEJET 2 hebt die Mukosa schnell und selektiv an. Das erzeugte Flüssigkeitskissen ist größer als bei einer Nadelinjektion. Dieses Kissen bildet einen Sicherheitsabstand zur Muskularis. Dadurch wird das Perforationsrisiko bei … Continue reading Wasserstrahl-unterstützte EMR im Colon ascendens mit ERBEJET® 2
During a vaginal hysterectomy the sacrouterine ligament was severed with the BiClamp® 201 T from Erbe. With the BiClamp® a minimum pain and bleeding thanks to reliable sealing of all vessels and tissue structures is … Continue reading Transection of the sacrouterine ligament with BiClamp® 201 T
Bipolar cutting and coagulating, dissecting and detaching of ligaments with the LAP BiSect Macro from Erbe during a laparoscopic-assisted vaginal hysterectomy (LAVH).
Endoskopische Resektion von submukosalen Tumoren mit dem HybridKnife® von Erbe. Das HybridKnife® vereint die Technologien Elektro- und Wasserstrahl-Chirurgie in einem Instrument. Das Ergebnis: eine intakte Mukosa und geschonte Muskularis.
Liver resection on a 2-month-old child with ERBEJET® 2 and further instruments from Erbe like the Applicator monopolar, a combination of waterjet with electrosurgery for a faster dissection, BiClamp® 150 C for an effective vessel … Continue reading Liver resection on a newborn child with ERBEJET® 2
Die „kühle“ Branche der BiClamp® reduziert das Verletzungsrisiko des Uterus. Eine optimale Fixierung des Gewebes durch die anatomisch angepasste Branchenform unterstützt den minimalinvasiven Charakter des Eingriffs der vaginalen Hysterektomie.
Der APCapplicator mit integriertem Filter – breites Applikationsspektrum aus Argonplasma-Koagulation und argonunterstützter Elektrochirurgie. Alles vereint im neuen Einweg Handgriff von Erbe. Besuchen Sie auch apc.erbe-med.com für weitere Informationen
Der APCapplicator mit integriertem Filter – breites Applikationsspektrum aus Argonplasma-Koagulation und argonunterstützter Elektrochirurgie. Alles vereint im neuen Einweg Handgriff von Erbe. Besuchen Sie auch apc.erbe-med.com für weitere Informationen
Der APCapplicator mit integriertem Filter – breites Applikationsspektrum aus Argonplasma-Koagulation und argonunterstützter Elektrochirurgie. Alles vereint im neuen Einweg Handgriff von Erbe. Besuchen Sie auch apc.erbe-med.com für weitere Informationen
Der APCapplicator mit integriertem Filter – breites Applikationsspektrum aus Argonplasma-Koagulation und argonunterstützter Elektrochirurgie. Alles vereint im neuen Einweg Handgriff von Erbe. Besuchen Sie auch apc.erbe-med.com für weitere Informationen
Der Chirurgiehandgriff von Erbe zum monopolaren Schneiden, Koagulieren und gleichzeitigen Rauchgasabsaugung.
Gynecological LEEP Conization with monopolar electrodes – the tungsten snare and the ball electrode.
Bipolar TURP with the new VIO® 3 mode highCUT bipolar. This new mode has been optimized for bipolar resection in a saline solution. The power peak system (PPS) enables rapid incision. The stable plasma facilitates … Continue reading Bipolar TURP with VIO® 3
Bipolar TURBT with the new VIO® 3 mode highCUT bipolar. This new mode has been optimized for bipolar resection in a saline solution. The power peak system (PPS) enables rapid incision. The stable plasma facilitates … Continue reading Bipolar TURBT with VIO® 3
Adhesions in the upper abdomen can be lysed very well with the LAP BiSect Micro. Bipolar cutting and coagulation, as seen here, where the omentum was dissected from the abdominal wall.
Proliferation of tumor tissue through the mesh of the esophageal stent often occurs when using non-coated metal stents. Argon plasma coagulation (APC) with flexible probes have proved to be very effective in removing such in- … Continue reading Ablation of esophageal stent ingrowth with APC 2
Thermal ablation of colorectal neoplasia with argon plasma coagulation (APC). Performed with the PULSED APC mode of the APC 2 from Erbe. Flexible APC probes with axial and lateral openings are applied.
Argon Plasma Coagulation (APC) has been used for thermal ablation of Barrett’s esophagus for years. The flexible HybridAPC probe from Erbe combines now APC with waterjet elevation to create a submucosal protective layer. HybridAPC enables … Continue reading Thermal ablation of Barrett´s remainder at GEJ with HybridAPC
The sacral colpopexy is the gold standard for descensus operations. It serves to restore the pelvic floor in case of prolapse complaints. The LAP BiSect Micro is ideally suited for this procedure. Bipolar dissection, cutting … Continue reading Laparoscopic sacral colpopexy with LAP BiSect Micro
Beim HybridAPC-Verfahren wird die Argonplasma-Koagulation (APC) jetzt mit einer Wasserstrahl-Funktion kombiniert. Vor der Ablation wird die Mukosa mit dem Hochdruck-Wasserstrahls der flexiblen HybridAPC-Sonde angehoben. Die vom Barrett befallene Mukosa kann durch das entstandene Wasserschutzkissen mit … Continue reading Ablation des Barrett-Ösophagus mit HybridAPC
The preciseSECT mode of the VIO® 3 is particularly well suited to mobilize the left colonic flexure and precisly dissect the mesorectum during a total mesorectal excision, TME for short.
The LAP BiSect Micro is an excellent instrument for mobilizing the colon during a hemicolectomy. Bipolar dissection, cutting and coagulation with this instrument enables laparoscopic surgery with a minimum need for equipment and instruments. With … Continue reading Laparoscopic omentectomy using LAP BiSect Micro
Preventing or controlling hemorrhage during parenchymal transection is the key for laparoscopic hepatic resection. Using the Erbejet 2 for hydrodissection, blood vessels and bile ducts are separated selectively from the parenchyma. Vessels can be treated … Continue reading Laparoscopic left hepatectomy for HCC with liver cirrhosis using hydrodissection and LAP BiSect Micro
Waterjet dissection combined with the sealing of exposed vessels in a laproscopic liver resection using the straight ERBEJET applicator with suction and the BiClamp LAP Maryland.
Erbe bietet für wichtige OP-Schritte einer Thyreoidektomie ein optimiertes, ergonomisches Instrument an, die BiClamp 150 C. Die Geometrie der Branchen und des Maulteils erlaubt den Eingriff auch bei engen Zugangswegen unter guter Sicht. Die BiClamp … Continue reading Minimal-invasive Thyreoidektomie mit BiClamp® 150 C
A combined approach using APC and subsequent mechanical tumor ablation (for example, using forceps) can be used to effectively treat patients with large tumors and life-threatening stenoses. The circular APC probe 2200, circular, was designed … Continue reading Recanalization of endobronchial tumor with APC 2
Die Gewebeselektivität des Wasserstrahls reduziert bei der Prostatektomie das Risiko von Sexual- und Blasenfunktionsstörungen. Blutgefäße und Nervenstränge bleiben bei der Wasserstrahl-Dissektion der Prostata mit dem ERBEJET 2 weitgehend intakt. Die Präparation des Gefäßnervenstranges zwischen Faszie … Continue reading Nerverhaltende radikale Prostatektomie durch Wasserstrahl-Dissektion mit ERBEJET® 2
A nerve-sparing laparoscopic prostatectomy with the ERBEJET 2 is shown here. The preparation of the neurovascular bundles between the parapelvic fascia and the prostatic capsule is carried out intermittently using both the waterjet itself and … Continue reading Prostatectomy, laparoscopic, with ERBEJET® 2
Alternating cutting and coagulation during polypectomy of a stalked polyp in the colon using VIO ENDO CUT Q Mode.
The multifunctional HybridKnife instrument not only supports the POEM procedure, it also simplifies the relevant steps. Thanks to the integrated electrosurgical and waterjet functions, both the time and effort required for peroral endoscopic myotomy is … Continue reading Peroral endoscopic myotomy (POEM) with HybridKnife T-Type
HybridKnife® optimiert die perorale, endoskopische Myotomie und vereinfacht die POEM-Arbeitsschritte. Mit Hilfe der Wasserstrahl-Elevation (ERBEJET 2) wird die Mukosa vor der Dissektion angehoben. Dieser Eingriff wurde von Prof. Dr. med H. Neuhaus mit dem HybridKnife … Continue reading POEM mit HybridKnife®, I-Typ
HybridKnife from Erbe optimizes Peroral Endoscopic Myotomy (POEM). The multifunctional HybridKnife instrument not only supports the POEM procedure, it also simplifies the relevant steps, especially the creation of a submucosal tunnel. Waterjet elevation establishes a … Continue reading POEM (submucosal tunneling) with HybridKnife®
Die kombinierte Wasserstrahl-Dissektion und HF-Koagulation mit dem ERBEJET 2 und dem Wasserstrahl-Applikator mit monopolarer HF-Funktion verbessert die OP-Performance bei der Nephrektomie.
The fractionated cutting mode ENDO CUT I is characterized by alternating cutting and coagulation cycles. This makes it possible to carry out controlled cutting with sufficient hemostasis during the entire cutting process, which supports the … Continue reading Papillotomy using ENDO CUT® I
Laparoscopic surgery for ovarian cancer usually means removing the uterus (hysterectomy) along with both ovaries and fallopian tubes (this is called a bilateral salpingo-oophorectomy or BSO). In addition, the omentum is also removed (an omentectomy). … Continue reading Omentectomy with hysterectomy using LAP BiSect Micro
The high-pressure waterjet of the ERBEJET 2 is used for selective dissection of the kidney parenchyma. Where required, the exposed vessels are coagulated, sealed and separated using the BiClamp LAP forceps.
The LAP BiSect enables bipolar laparoscopic exposure of the kidney with a minimum need for equipment and instruments. Easier, quicker, more effective and more cost-efficient. With its excellent preparation properties and effective coagulation and dissection, … Continue reading Laparoscopic partial nephrectomy with LAP BiSect Micro
Nerve sparing during a laparoscopic radical prostatectomy is crucial for a optimal post-sessional functional outcome. The use of the hydro-dissector ERBEJET® 2 from Erbe during this part of the surgery aids the dissection of the … Continue reading Nerve sparing laparoscopic radical prostatectomy with hydrodissection, intrafascial technique
Hemorrhage-free dissection of lymph notes with excellent dissection properties performed with Bipolar LAP scissor and assisted by the BiClamp® LAP (Kelly) from Erbe.
Living donor right hepatectomy (LDRH) is currently the most common donor surgery in adult-to-adult living donor liver transplantation (LDLT). Hydrodissection with the ERBEJET 2 is used in this case for – tissue-selective dissection of the … Continue reading Living donor right hepatectomy with ERBEJET® 2
Faster dissection in liver surgery The ERBEJET Applicator Monopolar combines waterjet surgery and electrosurgery functions. With the waterjet function, the blood vessels and bile ducts are dissected selectively. As soon as the blood vessels are … Continue reading Segmental liver resection with ERBEJET® Applicator Monopolar
Argon plasma coagulation (APC) treatment of ulcer-bed Forrest 1b bleeding with PULSED APC, Effect 2.