A histological option where you´ve had cytological sampling so far? Learn more about latest data on mediastinal cryobiopsy from Prof. Herth.

A histological option where you´ve had cytological sampling so far? Learn more about latest data on mediastinal cryobiopsy from Prof. Herth.
How to rapidly restore airway patency in a patient with a blood cast of the tracheobronchial tree? See Prof. Hetzel discuss how to perform cryoextraction of these blood clots.
To diagnose ILD, the flexible single-use cryoprobe with 1.7 mm was advanced into the periphery until the pleura and pulled back for 1cm. Fluoroscopy control was used for the positioning. After freezing for 5 seconds, … Continue reading Transbronchial cryobiopsy with rigid intubation for ILD diagnosis using flexible single-use cryoprobe and ERBECRYO® 2
The lung tumor was removed from its base with a monopolar snare and endoCUT Q (3-1-6). It was taken out of the lung with a flexible single-use cryoprobe 1.7 mm. More recanalization can be done … Continue reading Removal of a lung tumor with monopolar snare, flexible single-use cryoprobe and APC
Case history: Breast-cancer related mastectomy on the right side several years ago. Situation: Female patient admitted for further examination of fluid accumulation in the right pleural space. The dissemination of breast cancer had to be … Continue reading Pleuroscopic cryobiopsies using the flexible 1.7 mm single-use cryoprobe with ERBECRYO® 2
Dr. Stefan Barath, senior consultant and interventional lung oncologist at the Lund University Hospital, introduces us to his department, explains his working method and presents a transbronchial cryobiopsy with the new 2.4 mm and 1.1 … Continue reading Transbronchial cryobiopsy with single-use cryoprobe
Like cryobiopsies, the tumor can be frozen to the tip of the cryoprobe and removed. An effective cryorecanalization is thus possible in up to 91 % of the cases.
Argon plasma coagulation (APC) in flexible bronchoscopy is used to control bleeding in the tracheobronchial tract. See also in this case bleeding management with the flexible FiAPC® probe 1500 A after recanalization of an endobronchial … Continue reading Bleeding management after endobronchial recanalization with flexible FiAPC® probe 1500 A
The ERBECRYO® 2 is the next generation of cryo units and was designed with a focus on improved reproducibility for state-of-the-art flexible cryo applications. Several new features support ease-of-use and enhance the technical and clinical … Continue reading Flexible single-use cryoprobes for ERBECRYO® 2
Cryobiopsy is an established clinical application of the ERBECRYO® 2 with flexible cryoprobes. The flexible single-use cryoprobe with oversheath is our latest technology extension – measuring 1.1 mm, the thinnest cryoprobe in our portfolio. The … Continue reading Transbronchial cryobiopsies using the 1.1 mm single-use probe with oversheath