Skip to content
Medical Videos

Medical Videos

Medical product and application videos from Erbe

  • Products
    • Electrosurgery
    • Plasmasurgery
    • Thermofusion
    • Hydrosurgery
    • Cryosurgery
    • Setup videos
  • Applications
    • Surgery
    • Gastroenterology
    • Gynecology
    • Urology
    • Pulmonology
  • Education
  • Company
  •   DE   EN  

ERBEJET

POEM with HybridKnife®, VIO® 3 und ERBEJET® 2

Erbe-editor 2019-08-29

Endoscopic treatment of esophageal achalasia demonstrating the advantages of HybridKnife®, VIO® 3 and ERBEJET® 2 for peroral endoscopic myotomy (POEM).

Waterjet-assisted TEM-ESD of a large-scale rectal adenoma using the Surgery Workstation

Erbe-editor 2018-03-13

Waterjet-assisted TEM ESD using the Surgery Workstation (VIO® 3, ERBEJET® 2, APC 3) combines the advantages of transanal endoscopic microsurgery (TEM) and endoscopic submucosal dissection (ESD). High-pressure waterjet elevation using the ERBEJET® 2 in combination … Continue reading Waterjet-assisted TEM-ESD of a large-scale rectal adenoma using the Surgery Workstation →

Waterjet-assisted EMR of rectal adenoma with GI workstation

Erbe-editor 2017-10-10

The needleless waterjet elevation of the mucosa provided by the ERBEJET ® 2 of the GI Workstation (also consists of VIO® 200 D, APC 2, ENDO CUT Q) raises the mucosa quickly and selectively and … Continue reading Waterjet-assisted EMR of rectal adenoma with GI workstation →

Waterjet-assisted EMR of colonic adenoma with ERBEJET® 2

Erbe-editor 2017-10-05

The needleless waterjet elevation of the mucosa provided by the ERBEJET® 2 raises the mucosa quickly and selectively and generates a larger fluid cushion than with needle injection. The fluid cushion forms a safe margin … Continue reading Waterjet-assisted EMR of colonic adenoma with ERBEJET® 2 →

Liver resection on a newborn child with ERBEJET® 2

Erbe-editor 2017-09-29

Liver resection on a 2-month-old child with ERBEJET® 2 and further instruments from Erbe like the Applicator monopolar, a combination of waterjet with electrosurgery for a faster dissection, BiClamp® 150 C for an effective vessel … Continue reading Liver resection on a newborn child with ERBEJET® 2 →

Ablation of Barrett´s esophagus with HybridAPC

Erbe-editor 2017-08-21

In HybridAPC, argon plasma coagulation (APC) is now combined with a waterjet function. Prior to ablation, the mucosa is raised with the aid of the high-pressure waterjet of the flexible HybridAPC probe. The water cushion … Continue reading Ablation of Barrett´s esophagus with HybridAPC →

Laparoscopic liver resection with ERBEJET 2 and BiClamp LAP

Erbe-editor 2017-07-24

Waterjet dissection combined with the sealing of exposed vessels in a laproscopic liver resection using the straight ERBEJET applicator with suction and the BiClamp LAP Maryland.

Nerve sparing radical prostatectomy using ERBEJET® 2

Erbe-editor 2017-04-26

The selectivity of the waterjet reduces the risk of sexual dysfunction and/or urinary incontinence in prostatectomy procedures. Blood vessels and nerve cords remain largely intact during resection of the prostate. The preparation of the neurovascular … Continue reading Nerve sparing radical prostatectomy using ERBEJET® 2 →

Prostatectomy, laparoscopic, with ERBEJET® 2

Erbe-editor 2017-04-26

A nerve-sparing laparoscopic prostatectomy with the ERBEJET 2 is shown here. The preparation of the neurovascular bundles between the parapelvic fascia and the prostatic capsule is carried out intermittently using both the waterjet itself and … Continue reading Prostatectomy, laparoscopic, with ERBEJET® 2 →

Partial nephrectomy using the monopolar ERBEJET® applicator

Erbe-editor 2017-04-20

Combined waterjet dissection and electrocoagulation improves surgical performance of this procedure.

Posts navigation

← Older Posts

Erbe RSS Feed Subscribe to news

Recent Posts

  • Radical prostatectomy using the preciseSECT mode – targeted treatment of extracellular matrix
  • Webcast – Smoking prohibited – IES 3 in the operating room
  • Transbronchial cryobiopsy with rigid intubation for ILD diagnosis using flexible single-use cryoprobe and ERBECRYO® 2
  • Removal of a lung tumor with monopolar snare, flexible single-use cryoprobe and APC
  • Lateral neck dissection for metastatic thyroid carcinoma using BiClamp® 150 C and Bipolar Forceps PREMIUM

Most watched videos

  • Extended PLND for high risk prostate cancer using VIO® 3 preciseSECT 2,578 views
  • preciseSECT – the new VIO 3 mode 1,527 views
  • Thyroidectomy with BiClamp 110 566 views

Tag cloud

LAP BiSect Micro argon plasma coagulation VIO 3 handle ERBEJET 2 BiCision BiClamp vessel sealing ESD laparoscopic gastroenterology APC VIO biopsy electrosurgery HybridKnife ERBECRYO 2 dissection bronchoscopy ERBEJET

Contact

  • info@erbe-med.com
  • +49 7071 755-0
  • Erbe Website
  • Mobile Apps
  • Product catalog

Order hotline

For questions about orders, price inquiries, offers, article availability, delivery time

Tel. +49 7071 755-400

© Erbe Elektromedizin GmbH | Waldhörnlestrasse 17 | 72072 Tübingen | Germany - Imprint | Terms of trade | Information on Data Protection | Terms of Use