Skip to content
Medical Videos

Medical Videos

Medical product and application videos from Erbe

  • Products
    • Electrosurgery
    • Plasmasurgery
    • Thermofusion
    • Hydrosurgery
    • Cryosurgery
    • Setup videos
    • Imaging system
  • Applications
    • Surgery
    • Gastroenterology
    • Gynecology
    • Urology
    • Pulmonology
  • Education
  • Company
  •   DE   EN  

waterjet elevation

Rectal ESD of a sessile serrated lesion using HYBRIDknife® flex T-Type with VIO® 3 and ERBEJET® 2

Erbe-editor 2025-02-11

Prof. Jérémie Jacques performs and comments in a recorded live stream an endoscopic submucosal dissection, ESD of a sessile serrated lesion in the rectum using the HYBRIDknife® flex T-Type. He explains the advantages of the … Continue reading Rectal ESD of a sessile serrated lesion using HYBRIDknife® flex T-Type with VIO® 3 and ERBEJET® 2 →

ESD of recurrent colorectal adenoma with HybridKnife®

Erbe-editor 2017-10-06

After numerous endoscopic mucosal resection (EMR) attempts an en bloc endoscopic submucosal dissection (ESD) of the colorectal cancer with HybridKnife® was indicated. A partial muscle layer resection must also be carried out due to serious … Continue reading ESD of recurrent colorectal adenoma with HybridKnife® →

ESD of LST-NG tumor in distal sigmoid colon with HybridKnife®

Erbe-editor 2017-10-06

The integrated functions of waterjet surgery and electrosurgery in the HybridKnife enable endoscopic submucosal dissection (ESD) of a LST-NG (laterally spreading, non-granular type) tumor in the distal sigmoid colon.R0 resection of the adenoma with high … Continue reading ESD of LST-NG tumor in distal sigmoid colon with HybridKnife® →

ESD for early gastric cancer using HybridKnife®

Erbe-editor 2017-10-06

Waterjet elevation with the ERBEJET 2 and the HybridKnife prior to endoscopic submucosal dissection (ESD) is a protective and selective procedure. Selective elevation of the mucosa using a submucosal fluid cushion raises the resection level … Continue reading ESD for early gastric cancer using HybridKnife® →

Eradication of residual Barrett´s mucosa with HybridAPC

Erbe-editor 2017-10-06

Argon Plasma Coagulation (APC) has been used for thermal ablation of Barrett’s esophagus for years. The flexible HybridAPC probe from Erbe combines now APC with waterjet elevation to create a submucosal protective layer. HybridAPC enables … Continue reading Eradication of residual Barrett´s mucosa with HybridAPC →

En bloc resection of bladder tumors with HybridKnife

Erbe-editor 2017-10-05

The bladder tumor can be resected in one piece using the electrosurgery function of the HybridKnife instrument. By elevating the mucosa, the resection level is raised and the risk of perforation of the muscularis is … Continue reading En bloc resection of bladder tumors with HybridKnife →

Ablation of Barrett´s esophagus with HybridAPC

Erbe-editor 2017-08-21

In HybridAPC, argon plasma coagulation (APC) is now combined with a waterjet function. Prior to ablation, the mucosa is raised with the aid of the high-pressure waterjet of the flexible HybridAPC probe. The water cushion … Continue reading Ablation of Barrett´s esophagus with HybridAPC →

POEM with HybridKnife®, I-Type

Erbe-editor 2017-04-21

The HybridKnife® instrument optimizes peroral endoscopic myotomy by simplifying all relevant POEM steps. While alternating between the waterjet and the electrosurgical function of the HybridKnife, a submucosal tunnel is created. Thanks to the high-pressure waterjet … Continue reading POEM with HybridKnife®, I-Type →

POEM (submucosal tunneling) with HybridKnife®

Erbe-editor 2017-04-21

HybridKnife from Erbe optimizes Peroral Endoscopic Myotomy (POEM). The multifunctional HybridKnife instrument not only supports the POEM procedure, it also simplifies the relevant steps, especially the creation of a submucosal tunnel. Waterjet elevation establishes a … Continue reading POEM (submucosal tunneling) with HybridKnife® →

Erbe RSS Feed Subscribe to news

Recent Posts

  • VIO® 3n and VIO® seal – Tailored to sync with you
  • APC Ablation of ovarian endometrioma
    using APCapplicator
  • Rectal ESD of a sessile serrated lesion using HYBRIDknife® flex T-Type with VIO® 3 and ERBEJET® 2
  • Hysteroscopic transcervical resection of uterine septum (TCRS) using the bipolar 18.5 CH Mini Resectoscope with VIO® 3
  • Bipolar Mini Resectoscope 18.5 French with VIO® 3 for transcervical interventions / Testimonial by Dr. S. Izzo, Milan, Italy

Most watched videos

  • En bloc resection of bladder tumors with HybridKnife 16,557 views
  • The principle of the argon plasma coagulation 14,248 views
  • Vaginal hysterectomy with BiClamp® 201 T 9,290 views

Tag cloud

vessel sealing VIO 3 argon plasma coagulation APC gastroenterology dissection ESD HybridKnife LAP BiSect Micro POEM VIO precisesect BiClamp endoscopy cryo laparoscopic ERBEJET 2 ERBEJET cryoprobe electrosurgery

Contact

  • info@erbe-med.com
  • +49 7071 755-0
  • Erbe Website
  • Mobile Apps
  • Product catalog

Order hotline

For questions about orders, price inquiries, offers, article availability, delivery time

Tel. +49 7071 755-400

© Erbe Elektromedizin GmbH | Waldhörnlestrasse 17 | 72072 Tübingen | Germany - Imprint | Terms of trade | Information on Data Protection | Terms of Use