Discover VIO® seal, the first electrosurgical generator in the VIO® family dedicated entirely to bipolar applications. TriSect rapide® is your perfect combination for VIO® seal. Innovative jaw design of the TriSect rapide® allows you to … Continue reading VIO® seal and TriSect rapide® product movie – Advanced bipolar technology
Heterotopic gastric mucosa – APC ablation using the FiAPC® plus probe with pulsedAPC® E3.5
The 59-year-old patient suffers from severe laryngitis and chronic coughing. A possible cause is heterotopic gastric mucosa in the proximal esophagus. Argon plasma coagulation is performed by Dr. Torsten Beyna using the Erbe FiAPC® plus … Continue reading Heterotopic gastric mucosa – APC ablation using the FiAPC® plus probe with pulsedAPC® E3.5
ESD, colon, splenic flexure, using HYBRIDknife® fIex, I-type
An endoscopic submucosal dissection (ESD) of a LST-NG tumor at the splenic flexure is performed by Prof. A. Repici using the VIO® 3 Gastroenterology Workstation with HYBRIDknife® flex I-Type. This monopolar knife is tailored for … Continue reading ESD, colon, splenic flexure, using HYBRIDknife® fIex, I-type
ESD, gastric, for stomach neoplasia, with HYBRIDknife® flex, I-Type
HYBRIDknife® flex is an efficient instrument for applications in 3rd space endoscopy. In this case Dr. T. Beyna uses the HYBRIDknife® flex I-Type for endoscopic submucosal dissection (ESD) of stomach neoplasia. The VIO® 3 GI … Continue reading ESD, gastric, for stomach neoplasia, with HYBRIDknife® flex, I-Type
ESD, Cecum, using HYBRIDknife® flex I-type
This endoscopic submucosal dissection procedure is performed by Dr. Roberta Maselli at Humanitas Research Hospital, Milan, Italy. A patient with an LST mixed type tumor in the cecum is treated endoscopically with the HYBRIDknife® flex. … Continue reading ESD, Cecum, using HYBRIDknife® flex I-type
TCRF – Bipolar transcervical resection of fibroids with VIO® 3 and 18.5 CH Mini resectoscope. Imaged by VIRON 1 System.
The transcervical resection solution combines the VIRON 1 Imaging System with our VIO® 3 electrosurgical unit and the bipolar 18.5 CH Mini resectoscope. The highCUT bipolar mode of the VIO® 3 enables immediate, delay-free incision … Continue reading TCRF – Bipolar transcervical resection of fibroids with VIO® 3 and 18.5 CH Mini resectoscope. Imaged by VIRON 1 System.
Bipolar transcervical resection (TCR) of myomas with VIO® 3 and 18.5 CH Mini resectoscope. Imaging with VIRON 1 System
The transcervical resection solution combines the VIRON 1 Imaging System with our VIO® 3 electrosurgical unit and the bipolar 18.5 CH Mini resectoscope. The highCUT bipolar mode of the VIO® 3 enables immediate, delay-free incision … Continue reading Bipolar transcervical resection (TCR) of myomas with VIO® 3 and 18.5 CH Mini resectoscope. Imaging with VIRON 1 System
Laparoscopic living donor nephrectomy using TriSect rapide® and VIO® 3
Dr. Tiong performs key steps of a laparoscopic living donor nephrectomy with TriSect rapide® 350 and VIO® 3, including – Retroperitoneal incision and mobilization of the descending colon – Fast dissection of the vascular pedicle … Continue reading Laparoscopic living donor nephrectomy using TriSect rapide® and VIO® 3
VIO® 3 setup
Operating the VIO® 3 step by step. 00:08 Switch on the unit 00:22 Select program 00:28 Apply and connect neutral electrode 00:45 Monitor neutral electrode 00:51 Connecting the instrument 01:04 Checking the instrument settings 01:10 … Continue reading VIO® 3 setup
BiClamp® LAP and LAP BiSect in gynecological surgery – a testimonial by Dr. Ma Li, University Hospital Singapore
Sealing of vessels and tissue structures and precise bipolar dissection are important working steps in gynecological surgeries. Erbe therefore provides reliable and reusable surgical instruments – BiClamp® LAP and LAP BiSect Micro. Dr. Ma Li … Continue reading BiClamp® LAP and LAP BiSect in gynecological surgery – a testimonial by Dr. Ma Li, University Hospital Singapore