An endoscopic submucosal dissection (ESD) of a LST-NG tumor at the splenic flexure is performed by Prof. A. Repici using the VIO® 3 Gastroenterology Workstation with HYBRIDknife® flex I-Type. This monopolar knife is tailored for … Continue reading ESD, colon, splenic flexure, using HYBRIDknife® fIex, I-type
ESD, gastric, for stomach neoplasia, with HYBRIDknife® flex, I-Type
HYBRIDknife® flex is an efficient instrument for applications in 3rd space endoscopy. In this case Dr. T. Beyna uses the HYBRIDknife® flex I-Type for endoscopic submucosal dissection (ESD) of stomach neoplasia. The VIO® 3 GI … Continue reading ESD, gastric, for stomach neoplasia, with HYBRIDknife® flex, I-Type
ESD, Cecum, using HYBRIDknife® flex I-type
This endoscopic submucosal dissection procedure is performed by Dr. Roberta Maselli at Humanitas Research Hospital, Milan, Italy. A patient with an LST mixed type tumor in the cecum is treated endoscopically with the HYBRIDknife® flex. … Continue reading ESD, Cecum, using HYBRIDknife® flex I-type
DIES 2024 – Erbe Symposium / The knife of the future: experience with the new HYBRIDknife® flex
We were pleased to welcome a large number of renowned gastroenterologists during the DIES 2024 Erbe satellite symposium which was chaired by Prof. H. Neuhaus and Prof. A. Repici on February 2nd. If you were … Continue reading DIES 2024 – Erbe Symposium / The knife of the future: experience with the new HYBRIDknife® flex
TCRF – Bipolar transcervical resection of fibroids with VIO® 3 and 18.5 CH Mini resectoscope. Imaged by VIRON 1 System.
The transcervical resection solution combines the VIRON 1 Imaging System with our VIO® 3 electrosurgical unit and the bipolar 18.5 CH Mini resectoscope. The highCUT bipolar mode of the VIO® 3 enables immediate, delay-free incision … Continue reading TCRF – Bipolar transcervical resection of fibroids with VIO® 3 and 18.5 CH Mini resectoscope. Imaged by VIRON 1 System.
Bipolar transcervical resection (TCR) of myomas with VIO® 3 and 18.5 CH Mini resectoscope. Imaging with VIRON 1 System
The transcervical resection solution combines the VIRON 1 Imaging System with our VIO® 3 electrosurgical unit and the bipolar 18.5 CH Mini resectoscope. The highCUT bipolar mode of the VIO® 3 enables immediate, delay-free incision … Continue reading Bipolar transcervical resection (TCR) of myomas with VIO® 3 and 18.5 CH Mini resectoscope. Imaging with VIRON 1 System
Hysterectomy in case of laparoscopic treatment of deep infiltrating endometriosis (DIE) using TriSect rapide®
See the TriSect rapide® in use at a laparoscopic hysterectomy. The multi-tool dissects and excises the fallopian tube, transects the ovarian, round and broad ligaments, and dissects ureter and uterine pedicles. TriSect rapide is powered … Continue reading Hysterectomy in case of laparoscopic treatment of deep infiltrating endometriosis (DIE) using TriSect rapide®
Laparoscopic living donor nephrectomy using TriSect rapide® and VIO® 3
Dr. Tiong performs key steps of a laparoscopic living donor nephrectomy with TriSect rapide® 350 and VIO® 3, including – Retroperitoneal incision and mobilization of the descending colon – Fast dissection of the vascular pedicle … Continue reading Laparoscopic living donor nephrectomy using TriSect rapide® and VIO® 3
Electrosurgical adhesiolysis and dissection of endometriotic lesions in case of DIE using TriSect rapide®
Endometriosis electrosurgery removes endometriotic lesions and adhesions. The TriSect rapide® is ideally suitable for open and laparoscopic treatment of deep infiltrating endometriosis (DIE). Here you can follow the laparoscopic approach using this multi-tool powered by … Continue reading Electrosurgical adhesiolysis and dissection of endometriotic lesions in case of DIE using TriSect rapide®
Open hemicolectomy with TriSect rapide® 140 and VIO® 3
Open hemicolectomy with the new TriSect rapide® 140 and VIO® 3. Speed up your dissection and use decent hemostasis with thermoSECT whenever applicable and get even faster. Dissect sensitive structures and tissues precisely or bluntly … Continue reading Open hemicolectomy with TriSect rapide® 140 and VIO® 3